Product Details

Tantalum Wire

Review grade, standard, size, surface, inspection and packing details before quotation.

Tantalum Wire

Tantalum wire, Ø0.3 to 3.0 mm, in unalloyed and tungsten-bearing grades including UNS R05200, R05400, R05252 and R05255. State the exact UNS, delivery form and quantity basis on the RFQ.

  • DocumentsMTC and EN 10204 3.1 on request
  • TraceabilityHeat number and inspection scope confirmed
  • RFQ detailsGrade, standard, size, tolerance, quantity
  • PackingExport protection by product form and length

Product Introduction

Ø0.3 to 3.0 mmPublished wire diameter range
UNS R05200 / UNS R05400 / Ta-2.5W / Ta-10WWire grades include
ASTM B365Rod and wire scope
By agreementSurface and delivery condition
The drawing controls the tantalum wire diameter. Name the exact UNS and receiving condition so material identity, dimensions and quantity can be reviewed on the same quotation.

Beiyu Titanium's published supply range for tantalum wire is Ø0.3 to 3.0 mm. Wire grades include UNS R05200, UNS R05400, UNS R05252 and UNS R05255; state the required identity, delivery condition and acceptance basis on your enquiry.

Tantalum category and exact grade selection

Which tantalum wire identity belongs on the RFQ?

State the exact UNS rather than a general tantalum description. Preserve the drawing's distinction between an unalloyed grade and a tungsten-bearing grade so the material document can be reviewed against the same specification. Give the UNS and required condition; Beiyu checks the designation at quotation.

Wire grades includeMaterial identityRFQ action
UNS R05200EB-melted tantalumState this exact UNS if the drawing calls for it
UNS R05400Powder metallurgy tantalumDo not substitute a general unalloyed label
UNS R05252Ta-2.5WRetain the alloy designation
UNS R05255Ta-10WRetain the alloy designation and name the governing specification

The material identities are also described on tantalum plate and sheet.

How can drawing diameter be converted to wire mass?

The diameters in this table are example inputs for the arithmetic within Beiyu Titanium's published supply range. Use g/m = ρ × π/4 × d², with d in mm and ρ = 16.69 g/cm³, Beiyu's reference density, used in our quotation weights, for unalloyed tantalum. Confirm the estimating basis for an alloy grade, whose density need not equal this reference.

Example diameter (mm)Calculated mass (g/m)Metres per kg
0.301.18847.6
0.503.28305.2
1.0013.1176.3
2.0052.4319.1
3.00117.978.5

Metres per kg = 1000 ÷ (g/m), calculated before rounding the mass per metre.

Verify the drawing diameter, quantity basis and required grade on the quotation before translating length into an order weight.

Cut wire lengths, illustrative image of the product form
Cut-length reference: identify the required piece geometry.
Coiled wire, illustrative image of the product form
Coiled-form reference for the handling decision on the RFQ.
Wire on spools, illustrative image of the product form
Spool reference: confirm the receiving requirement with the quantity basis.

What should be settled before quoting tantalum wire?

Settle the drawing diameter and receiving arrangement with the material specification. For an assembly that needs cut pieces, give piece length and straightened delivery; a total wire weight leaves piece count and handling unresolved. Include the drawing revision so the quotation identifies the intended cut pieces.

Quotation decisionInput requiredOrder check
DiameterSelect within Ø0.3 to 3.0 mm; give the drawing diameterConfirm the drawing revision and nominal value
ToleranceAs agreed on the orderState dimensional acceptance and measurement scope
DeliveryCoiled or straightened, as agreed on the orderCheck alignment with receiving equipment
SurfaceSurface condition as agreed on the orderRequest the condition and verify its quoted acceptance basis
Length basisSpool requirement or cut-piece length, with total quantityAgree the quantity that governs receipt

Which application information supports material review?

Tantalum is used for capacitor anodes, electronics and chemical-process parts. Wire suitability is reviewed for the actual component. Provide composition and operating conditions for any process media involved, since an application name does not establish corrosion performance.

Information to sendReview result needed
Component and service descriptionYour engineering team confirms the specified tantalum grade
Drawing, surface and delivery shapeQuotation identifies dimensional and handling requirements
Inspection and material documentsMTC or COC and traceability included when ordered

If the part is tubular, use tantalum pipe and tube; a material comparison can start with niobium wire.

FAQ

What tantalum wire diameters can I specify?
Beiyu Titanium's published supply range for tantalum wire is Ø0.3 to 3.0 mm. State your nominal diameter and tolerance on the drawing; the quotation records the dimensions for your order.

Is the word tantalum enough to identify the wire?
No. Include the UNS on the RFQ whenever the drawing specifies one, since the wire grades include distinct unalloyed and alloy identities. Supply the material requirement and check the quoted UNS and document scope against it before approval.

Does the 16.69 g/cm³ estimate apply to Ta-2.5W and Ta-10W wire?
It is the reference density for unalloyed tantalum. The tungsten-bearing grades differ, so for an alloy order confirm the estimating basis at quotation and let length or piece count govern the order.

Specification detail with sources

Beiyu Titanium's published supply range for tantalum wire is Ø0.3 to 3.0 mm. Beiyu's tantalum wire grades include UNS R05200 (EB-melted), UNS R05400 (powder metallurgy), UNS R05252 (Ta-2.5W) and UNS R05255 (Ta-10W). Beiyu's reference density, used in our quotation weights, is 16.69 g/cm³ for tantalum.

ASTM B365 covers tantalum and tantalum alloy rod and wire; the ASTM store and GlobalSpec scope listings name UNS R05200, UNS R05400, UNS R05252, UNS R05255 and UNS R05240. Identify the exact grade and acceptance requirements when the drawing invokes this specification; the scope listing does not define the ordered dimensions.

For standard grades and sizes the typical lead time is 15 to 30 days from order confirmation or deposit to ex-works dispatch, sea transit time not included; special chemistry or mechanical requirements call for an adjusted melt recipe, so their lead time depends on the requirements and is confirmed with the quotation.

Provide your tantalum wire drawing with the exact grade, diameter and piece length; include surface and packing criteria so the quoted delivery condition can be checked before purchase.

Submit a tantalum wire drawing
WhatsApp
WeChat
WeChat:
13575356867
Scroll to Top